摘要

The present study aimed to establish and evaluate a method for recording edentulous jaw relations digitally without occlusal bases, using a handheld scanner and specially designed headgear. The headgear maintained the mandibular position. Ten edentulous patients' upper (U) and lower edentulous jaw models (L) were prepared and scanned. A handheld scanner was used to capture the labial alveolar ridge mucosa relations in the upper and lower anterior arches directly (Dr). U and L were registered to Dr (test group). Complete dentures of patients in the intercuspal position were used to construct the relationship between U and L (control group). Differences in jaw relations in the test and control groups, in terms of vertical difference, displacement and rotation of the anterior and posterior, and displacement and rotation of the left and right were assessed using the Hotelling's T-2 test. The differences in the mean values and the mean of the absolute values of the jaw relations between groups were not statistically significant (P = 0.331) and significant (P = 0.016), respectively. Our findings show that it is possible to make digital recording of edentulous jaw relations by using a handheld scanner and headgear.

全文