Does Radiographic Beam Angle Affect the Radiocapitellar Ratio Measurement of Subluxation in the Elbow?

作者:McCann Fannie; Canet Fanny; Sandman Emilie; Petit Yvan; Rouleau Dominique M*
来源:Clinical Orthopaedics and Related Research, 2013, 471(8): 2556-2562.
DOI:10.1007/s11999-013-3027-2

摘要

Radial head alignment is the key to determine elbow reduction after treatment of subluxations or Monteggia fractures. The radiocapitellar ratio (RCR) quantifies the degree of subluxation, by evaluating radial head alignment with the capitellum of the humerus; this ratio is reproducible when measured on true lateral radiographs of nonsubluxated elbows. However, the impact of beam angulation on RCR measurement is unknown. Our hypotheses were that the RCR of the nonsubluxated elbow would remain in the normal range as the beam angle changed and that the RCR variability would increase for the subluxated elbow with small deviations in the beam angle. Radiographs were taken of six healthy cadaveric extremities using beam angles ranging from -20A degrees to 20A degrees along the inferosuperior axis and from -20A degrees to 20A degrees along the dorsoventral axis. The same views then were taken of the six arms with anterior radiocapitellum subluxation followed by posterior radiocapitellum subluxation. RCRs were measured by one observer. As a reference value, the RCR was measured in the 0A degrees to 0A degrees position and the difference between each RCR in a nonreference position was subtracted from each RCR reference to obtain the delta-RCR. An ANOVA was performed to assess the main and interactive effects on the RCR measured in each C-arm position compared with the RCR measured on a true lateral radiograph. The RCR remained in the normal range even as the beam angle of the C-arm varied between -20A degrees and 20A degrees. The position of the beam did not affect the RCR in anteriorly subluxated elbows (p = 0.777), whereas RCR variation increased especially in the presence of posterior radial head subluxation when the C-arm position was 10A degrees or more out of plane (p = 0.006). The inferosuperior malposition of the C-arm had a greater impact on quantification of radial head alignment measurement. Despite that, the RCR measurement is reliable in reduced and subluxated elbows on lateral radiographs with a C-arm position deviation of as much as 20A degrees. Identification of a subluxated elbow could be made on any lateral radiograph with a beam angulation deviation of as much as 20A degrees. This suggests that the RCR is a useful diagnostic tool for clinical and research purposes, although for subluxated elbows, it is important to pay careful attention to the inferosuperior position of the C-arm.

  • 出版日期2013-8