The control of the residual electric charge carried by granular materials processed in various electrostatic installations is a prerequisite for the safe and efficient operation of the respective industrial equipment. The aim of the present work was to evaluate the neutralization efficiency of polyethylene granules exposed to an AC corona discharge from a wire-type electrode. The control variables and their domains of variations were the following: the amplitude and the frequency of the applied high voltage (16-18 kV, 20-400 Hz), the position of the corona electrode (3-7 cm above the ground plate that carries the sample) and the duration of the exposure to the corona discharge (4-10 s). The surface potential decay method was used for monitoring the charge carried by granular samples of PE before and after neutralization. Design of experiment methodology was employed to evaluate the influence of each of the above mentioned control variables and determine the optimum operation conditions. The efficiency of the neutralization was characterized by the ratio between the values of the surface potential before and after AC corona discharge exposure. The obtained results show that neutralization efficiency may be improved by increasing the frequency of the high voltage as well as by adequately correlating its amplitude with the inter-electrode spacing.