Anti-floating checking calculation is indispensable in the design of buried horizontal tank, in addition to the structure strength and stability to meet the requirements. A new checking calculation method propounded by synthesizing analysis and comparison drawbacks in the several existing anti-floating checking methods, and this method takes into account the effect of different environmental conditions to the anti-floating stability of buried tank. The calculation shows that the new method can effectively improve the anti-floating stability of buried tank. Anti-floating measures must be adopted to prevent tank floating if the anti-floating stability conditions are not being met.