Assessment of fissionable material behaviour in fission chambers

作者:Cabellos O*; Fernandez P; Rapisarda D; Garcia Herranz N
来源:Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment , 2010, 618(1-3): 248-259.
DOI:10.1016/j.nima.2010.02.114

摘要

A comprehensive study is performed in order to assess the pertinence of fission chambers coated with different fissile materials for high neutron flux detection. Three neutron scenarios are proposed to study the fast component of a high neutron flux: (i) high neutron flux with a significant thermal contribution such as BR2, (ii) DEMO magnetic fusion reactor, and (iii) IFMIF high flux test module.
In this study, the inventory code ACAB is used to analyze the following questions: (i) impact of different deposits in fission chambers: (ii) effect of the irradiation time/burn-up on the concentration: (iii) impact of activation cross-section uncertainties on the composition of the deposit for all the range of burn-up/irradiation neutron fluences of interest. The complete set of nuclear data (decay, fission yield, activation cross-sections, and uncertainties) provided in the EAF2007 data library are used for this evaluation.

  • 出版日期2010-6-1