摘要

The new stir-bar coating based on silica gel modified with ketoimine groups was applied to the preconcentration of phenolic endocrine disruptors and heavy metal ions such as Cu-II, Cr-III and Ni-II in water samples followed by determination using LD-GC/MS and ICP-OES, respectively.

  • 出版日期2013-4