Analysis of diffusion process and influence factors in the air ingress accident of the HTR-PM

作者:Zheng Yanhua*; Chen Fubing; Shi Lei
来源:Nuclear Engineering and Design, 2014, 271: 397-403.
DOI:10.1016/j.nucengdes.2013.12.008

摘要

Air ingress, one of the beyond design basis accidents for high temperature gas-cooled reactors, receives high attention during the design of the 250 MW pebble-bed modular high temperature gas-cooled reactor (HTR-PM), because it may result in severe consequence including the corrosion of the fuel element and graphite reflector. The diffusion process and the set-up time of the stable natural convection after the double-ended guillotine break of the hot-gas duct are studied in the paper. On the basis of the preliminary design of the HTR-PM and its DLOCA analysis results, the diffusion process, as well as the influence of the core temperature distribution and the length of the hot-gas duct, is studied with the DIFFLOW code, which adopts a one-dimension variable cross-section diffusion model with fixed wall temperature. To preliminarily estimate the influence of chemical reaction between oxygen and graphite, which will change the gas component of the mixture, the diffusion processes between the He/N-2, He/O-2, He/CO and He/CO2 are calculated, respectively. Furthermore, the code has been improved and the varying wall temperature can be simulated. The more accurate analysis is carried out with the changing temperature distribution from the DLOCA calculation. The analysis shows that there is enough time to adopt appropriate mitigation measures to stop the air ingress and the severe consequence of fuel element damage and large release of fission product can be avoided.