Arm Raising at Exposure-controlled Multidetector Trauma CT of Thoracoabdominal Region: Higher Image Quality, Lower Radiation Dose

作者:Brink Monique*; de lange Frank; Oostveen Luuk J; Dekker Helena M; Kool Digna R; Deunk Jaap; Edwards Michael J R; van Kuijk Cornelis; Kamman Richard L; Blickman Johan G
来源:Radiology, 2008, 249(2): 661-670.
DOI:10.1148/radiol.2492080169

摘要

Purpose: To evaluate the effect of arm position on image quality and effective radiation dose in an automatic exposure-controlled (AEC) multidetector thoracoabdominal computed tomography (CT) protocol in trauma patients.
Materials and Methods: This retrospective study of the data of 177 trauma patients (117 male; median age, 39 years) was approved by the institutional ethics board, with informed patient consent waived. Patients underwent scanning by using an AEC 16-detector thoracoabdominal CT protocol in which both arms were raised above the shoulder region (standard-position group, 132 patients), one arm was raised and the other was down (one-arm group, 27 patients), or both arms were down (two-arm group, 18 patients). Objective and subjective image quality was assessed. Individual effective radiation dose was calculated from the effective tube current-time product per exposed section. For this purpose, section location-dependent conversion factors were derived by using a CT dosimetry calculator. The effect of arm position on effective dose was quantified by using linear regression analysis with correction for patient volume and attenuation.
Results: Compared with the image quality in the standard-position group, the image quality in the one- and two-arm groups was decreased but within acceptable diagnostic limits. The median corrected effective dose in the standard-position group was 18.6 mSv; the dose in the one- arm group was 18% (95% confidence interval: 11%, 25%) higher than this, and that in the two-arm group was 45% (95% confidence interval: 34%, 57%) higher.
Conclusion: Omitting arm raising results in lower but acceptable image quality and a substantially higher effective radiation dose. Hence, effort should be made to position the arms above the shoulder when scanning trauma patients.

  • 出版日期2008-11