Assessment of nodal target definition and dosimetry using three different techniques: implications for re-defining the optimal pelvic field in endometrial cancer

作者:Guo Susan; Ennis Ronald D*; Bhatia Stephen; Trichter Frieda; Bashist Benjamin; Shah Jinesh; Chadha Manjeet
来源:Radiation Oncology, 2010, 5: 59.
DOI:10.1186/1748-717X-5-59

摘要

Purposes: 1. To determine the optimal pelvic nodal clinical target volume for post-operative treatment of endometrial cancer. 2. To compare the DVH of different treatment planning techniques applied to this new CTV and the surrounding tissues.
Methods and Materials: Based on the literature, we selected a methodology to delineate nodal target volume to define a NEW-CTV and NEW-PTV. Conventional 2D fields, 3D fields based on anatomic guidelines per RTOG 0418, 3D fields based on our guidelines, and IMRT based on our guidelines were assessed for coverage of NEW-CTV, NEW-PTV, and surrounding structures. CT scans of 10 patients with gynecologic malignancies after TAH/BSO were used. DVHs were compared.
Results: For NEW-PTV, mean V45Gy were 50% and 69% for 2D and RTOG 0418-3DCRT vs. 98% and 97% for NEW-3DCRT and NEW-IMRT (p < 0.0009). Mean V45Gy small bowel were 24% and 20% for 2D and RTOG 0418-3DCRT, increased to 32% with NEW-3DCRT, and decreased to 14% with IMRT (p = 0.005, 0.138, 0.002). Mean V45Gy rectum were 26%, 35%, and 52% for 2D, RTOG 0418-3DCRT, and NEW-3DCRT, and decreased to 26% with NEW-IMRT (p < 0.05). Mean V45Gy bladder were 83%, 51%, and 73% for 2D, RTOG 0418-3DCRT, and NEW-3DCRT, and decreased to 30% with NEW-IMRT (p < 0.002).
Conclusions: Conventional 2D and RTOG 0418-based 3DCRT plans cover only a fraction of our comprehensive PTV. A 3DCRT plan covers this PTV with high doses to normal tissues, whereas IMRT covers the PTV while delivering lower normal tissue doses. Re-consideration of what specifically the pelvic target encompasses is warranted.

  • 出版日期2010-6-27