Measurement of performance of thermoacoustic heat pump in a-3 to 160 degrees C temperature range

作者:Kikuchi Ryo*; Tsuda Kenichiro; Bassem Mohamed Mehdi; Ueda Yuki
来源:Japanese Journal of Applied Physics, 2015, 54(11): 117101.
DOI:10.7567/JJAP.54.117101

摘要

A thermoacoustic heat pump was constructed and tested. It was composed of a looped tube, a straight tube, and a regenerator. The looped tube contained the regenerator and was connected to the straight tube. The tubes were filled with nitrogen. When an acoustic wave was input to the tubes, a temperature difference formed along the regenerator. Our experiments showed that this heat pump could work as both a cooler and a heater. This heat pump achieved -39 degrees C as a cooler and 270 degrees C as a heater. Using antifreeze liquid and oil as heat media, the cooling and heating performance of the heat pump was measured within the temperature range from -3 to 160 degrees C.

  • 出版日期2015-11