A simple method for pre-calibration storage of sulphur hexafluoride permeation tubes

作者:Deighton M H*; O'Loughlin B M; Buckley F; Boland T M
来源:Animal Feed Science and Technology, 2011, 166-67: 198-200.
DOI:10.1016/j.anifeedsci.2011.04.011

摘要

Long term storage of sulphur hexafluoride (SF(6)) permeation tubes, used to determine enteric emissions from ruminants using a calibrated tracer (ERUCT) technique, is desirable to increase flexibility of post-manufacture tube handling. To be effective, such storage must decouple the date of tube manufacture from the date of subsequent expiration due to gas loss. We hypothesized that release of SF(6) gas could be effectively inhibited by freezing tubes at -80 degrees C without affecting their subsequent performance. Thirty permeation tubes with mean SF(6) content of 3.081 g were blocked by SF(6) content and randomly allocated to one of two treatments being: immediate incubation at 39 degrees C, or incubation at 39 degrees C following 75 d storage at -80 degrees C. The SF(6) permeation rate at 39 degrees C of all tubes was determined by repeated weighing over a 50 d period. Storage of permeation tubes at -80 degrees C effectively inhibited release of SF(6) but had no effect on subsequent permeation rate at 39 degrees C. Deep frozen storage offers improved flexibility in handling of SF(6) permeation tubes for the ERUCT technique.
This article is part of the special issue entitled: Greenhouse Gases in Animal Agriculture Finding a Balance between Food and Emissions, Guest Edited by T.A. McAllister, Section Guest Editors; K.A. Beauchemin, X. Hao, S. McGinn and Editor for Animal Feed Science and Technology, P.H. Robinson.

  • 出版日期2011-6-23