摘要

The effect of conveyor speed, test sample size, antenna to sample distance, antenna polarization and ideal tag location in relation to the coupling capabilities of ultra-high frequency radio frequency identification on optimal reader antenna placement were studied. The influence of each individual factor and its interaction was determined using the general linear model analysis of variance. In decreasing order of significance of the variables tested were sample type (F = 4174.40, p < 0.0005), smaller samples preferred for coupling; distance (F = 863.83, p < 0.0005), where distance between sample and antenna should be kept to a minimum; inlay design (F = 167.82, p < 0.0005), where AD-612 preformed best due to its large antenna area; and reader antenna polarization (F = 149.64, p < 0.0005), where circular polarization preformed better yet comparative advantage decreased with distance. A reader antenna offset of 95 mm, while not significant, (F = 1.73, p = 0.188) tended to decrease coupling capabilities of the system despite increasing the zone of influence. Ideal tag location on sample was found to be on the right, back and front face with y-orientation proving superior than either x or z. A 190-mm centre-to-centre reader antenna offset resulted in a decrease in the average tag detection rate from 62 to 49% highlighting the importance of optimal reader antenna placement which needs to be confirmed if a similar result is to be obtained when a large number of tags are interrogated simultaneously.

  • 出版日期2010-10