A whole blood in vitro cytokine release assay with aqueous monoclonal antibody presentation for the prediction of therapeutic protein induced cytokine release syndrome in humans

作者:Wolf Babette; Morgan Hannah; Krieg Jennifer; Gani Zaahira; Milicov Adriana; Warncke Max; Brennan Frank; Jones Stewart; Sims Jennifer; Kiessling Andrea*
来源:Cytokine, 2012, 60(3): 828-837.
DOI:10.1016/j.cyto.2012.08.018

摘要

The administration of several monoclonal antibodies (mAbs) to humans has been associated with acute adverse events characterized by clinically significant release of cytokines in the blood. The limited predictive value of toxicology species in this field has triggered intensive research to establish human in vitro assays using peripheral blood mononuclear cells or blood to predict cytokine release in humans. A thorough characterization of these assays is required to understand their predictive value for hazard identification and risk assessment in an optimal manner, and to highlight potential limitations of individual assay formats. We have characterized a whole human blood cytokine release assay with only minimal dilution by the test antibodies (95% v/v blood) in aqueous presentation format, an assay which has so far received less attention in the scientific world with respect to the evaluation of its suitability to predict cytokine release in humans. This format was compared with a human PBMC assay with immobilized mAbs presentation already well-characterized by others. Cytokine secretion into plasma or cell culture supernatants after 24 h incubation with the test mAbs (anti-CD28 superagonist TGN1412-like material (TGN1412L), another anti-CD28 superagonistic mAb (ANC28.1), a T-cell depleting mAb (Orthoclone (TM)), and a TGN1412 isotype-matched control (Tysabri (TM)) not associated with clinically-relevant cytokine release) was detected by a multiplex assay based on electrochemiluminescent excitation. We provide proof that this whole blood assay is a suitable new method for hazard identification of safety-relevant cytokine release in the clinic based on its ability to detect the typical cytokine signatures found in humans for the tested mAbs and on a markedly lower assay background and cytokine release with the isotype-matched control mAb Tysabrin (TM) - a clear advantage over the PBMC assay. Importantly, quantitative and qualitative differences in the relative cytokine responses to the individual mAbs, in the concentration-response relationships and the prominent cytokine signatures for individual mAbs in the two formats reflect diverging mechanisms of cytokine release and different levels of dependency on high density coating even for two anti-CD28 super-agonistic antibodies. These results clearly show that one generic approach to assessment of cytokine release using in vitro assays is not sufficient, but rather the choice of the method, i.e. applying the whole blood assay or the PBMC assay needs to be well considered depending on the target characteristics and the mechanistic features of the therapeutic mAbs being evaluated.

  • 出版日期2012-12