Miniaturized hollow fiber assisted liquid-phase microextraction and gas chromatography-mass spectrometry for determination of benzophenone and derivates in human urine sample

作者:Kawaguchi Migaku; Ito Rie; Honda Hidehiro; Koganei Youji; Okanouchi Noriya; Saito Koichi; Seto Yasuo; Nakazawa Hiroyuki*
来源:Journal of Chromatography B-Analytical Technologies in the Biomedical and Life Sciences, 2009, 877(3): 298-302.
DOI:10.1016/j.jchromb.2008.12.021

摘要

The determination of benzophenones (BPs) in human urine sample by miniaturized hollow fiber assisted liquid-phase microextraction (HF-LPME) and gas chromatography-mass spectrometry (CC-MS) is described. As analytes, BP, its metabolites benzhydrol (BP-CH) and 2-hydroxybenzophenone (20H-BP), and its derivatives 2-hydroxy-4-methoxybenzophenone (BP-3) and 2-hydroxy-4-methoxy-4'-methylbenzophenone (BP-10) were selected. The detection limit and the quantification limit of BPs in human urine sample are 5-10 and 20-50 pg mL(-1), respectively. The calibration curve for BPs is linear with correlation coefficient higher than 0.99 in the range of 0.02-10 or 0.05-10 ng mL(-1). The average recoveries of BPs in human urine samples spiked with 0.5 and 5 ng mL(-1) BPs are 89.8-100.2% (RSD: 2.5-9.3%) and 89.3-99.9% (RSD: 2.9-3.7%), respectively. Ten human urine samples were analyzed using the present method. BP-CH and BP-3 were detected in all the samples within the range of 0.24-5.91 and 0.43-5.17 ng mL(-1). respectively. This simple, sensitive, and selective analytical method was successfully applied to the determination of trace amounts of BPs in human urine samples.

  • 出版日期2009-1-15