Novel Magnetic Resonance Imaging for Assessment of Bronchial Stenosis in Lung Transplant Recipients

作者:Mahmood K*; Ebner L; He M; Robertson S H; Wang Z; McAdams H P; Wahidi M M; Shofer S L; Huang Y T; Driehuys B
来源:American Journal of Transplantation, 2017, 17(7): 1895-1904.
DOI:10.1111/ajt.14287

摘要

Bronchial stenosis in lung transplant recipients is a common disorder that adversely affects clinical outcomes. It is evaluated by spirometry, CT scanning, and bronchoscopy with significant limitations. We hypothesize that MRI using both ultrashort echo time (UTE) scans and hyperpolarized (HP) Xe-129 gas can offer structural and functional assessment of bronchial stenosis seen after lung transplantation. Six patients with lung transplantation-related bronchial stenosis underwent HP Xe-129 MRI and UTE MRI in the same session. Three patients subsequently underwent airway stent placement and had repeated MRI at 4-week follow-up. HP Xe-129 MRI depicted decreased ventilation distal to the stenotic airway. After airway stent placement, MRI showed that low-ventilation regions had decreased (35% vs. 27.6%, p = 0.006) and normal-ventilation regions had increased (17.9% vs. 27.6%, p = 0.04) in the stented lung. Improved gas transfer was also seen on Xe-129 MRI. There was a good correlation between UTE MRI and independent bronchoscopic airway diameter assessment (Pearson correlation coefficient = 0.92). This pilot study shows that UTE and HP Xe-129 MRI are feasible in patients with bronchial stenosis related to lung transplantation and may provide structural and functional airway assessment to guide treatment. These conclusions need to be confirmed with larger studies.

  • 出版日期2017-7