Dislocation rate after hip arthroplasty within the first postoperative year: 36mm versus 28mm femoral heads

作者:Bistolfi Alessandro*; Crova Maurizio; Rosso Federica; Titolo Paolo; Ventura Stefano; Massazza Giuseppe
来源:HIP International, 2011, 21(5): 559-564.
DOI:10.5301/HIP.2011.8647

摘要

Dislocation is a common and important complication of total hip arthroplasty (THA). Larger femoral heads may reduce the risk of dislocation and improve the range of movement. The aim of this study was to compare the relative risk (RR) of dislocation during the first year after THA between implants with 28mm and 36mm femoral heads. 198 consecutive hips with 28mm femoral head (Group-28) and 259 hips with 36mm femoral head (Group-36) were studied. The patients were assessed preoperatively and periodically using the Harris hip score (HHS) and radiographic analysis. The relative risk (RR) of dislocation was calculated. The average HHS significantly improved from a preoperative baseline to the last follow-up at 82.1 months (28mm) and 44.3 months (36mm). No statistically significant differences were revealed between the two groups for HHS results and complications (p > 0.05), but the difference in RR of dislocation within the first year between the two groups was 7.85 (95% CI: 1.34-46.03), p = 0.046. Although dislocation is multifactorial in etiology, the two groups were homogenous for all principal contributing factors except the diameter of the femoral head. Therefore, the use of 36-mm heads can reduce the risk of dislocation following THA by a factor of 8 compared to conventional 28mm heads.

  • 出版日期2011-10