Analytical reconstruction of the bioluminescent source with priors

作者:Erkol Hakan*; Demirkiran Aytac; Uluc Nasire; Unlu Mehmet B
来源:Optics Express, 2014, 22(16).
DOI:10.1364/OE.22.01914119758

摘要

Bioluminescence imaging has been a popular tool in small animal imaging. During the last decade, the efforts have focused on the development of tomographic systems. However, due to the difficulties in the nature of inverse source problem, multi-modal systems have been the center of attention for the last couple of years. These systems provide complementary information such that the difficulties of the inverse source problem could be overcome using the a priori information obtained. Motivated by these advances in multi-modal systems, this work presents a novel analytical reconstruction of the bioluminescent source. It is shown that if source strength is known a priori then source position could be calculated or vice versa, if source location is known a priori, source strength could be calculated as well as the photon fluence rate. The determination of the source location can be achieved by another imaging system such as X-ray computed tomography. Therefore, in bioluminescence tomography together with an imaging system can be utilized as a multi-modal system. In this work, conventional finite element based simulations are also performed and the numerical results are compared with the analytical ones. It turns out to be that the analytical results are in a good accordance with the numerical results.

  • 出版日期2014-8-11

全文