摘要

In this paper the insulation resistances of the concrete structures of a high-speed rail transit system viaduct are analysed by means of an equivalent circuit. It is shown that the insulation resistances between a span and its respective piers and between adjacent spans depend on the earth wire to rebar resistance of the spans. The insulation resistances measured during the construction stages of the Ticino viaduct of the Italian ac high-speed line are used to estimate the earth wire to rebar resistance in three sections of the viaduct with different characteristics. The variation of the earth wire to rebar resistance along the viaduct can be related to the type, extension and progressive installation of metallic fixed structures in the spans. A good agreement between the viaduct insulation resistances calculated with the equivalent circuit and the measurements is found. An assessment of the stray current interference on a viaduct span is made with reference to the standard EN 50122-2:2010.

  • 出版日期2013-10