摘要

No consensus has yet been reached regarding the optimal mesh for the repair of small ventral hernias. A composite polytetrafluoroethylene/polypropylene mesh (Ventralex(A (R))) is designed for this purpose, and this paper reports its use in a larger series of patients. Open repair for a small ventral hernia was undertaken in 152 patients between April 2006 and June 2008. Data from medical files were gathered, and follow-up questionnaires were retrieved. Patients were asked about pain, intake of analgesics and various physical capabilities. Patients with postoperative complaints were offered a follow-up visit. Ultrasonography was performed if recurrence was suspected. Median surgery time was 39 min (range 16-129 min). Junior surgeons performed 63% of the operations. Questionnaires were returned by 81.6% with a mean follow-up of 15.6 months. Eighteen patients (11.8%) had complications. Pain score was significantly lower and the physical capabilities of the patients were significantly enhanced after the operation. Recurrent hernia was reported in four patients (2.6%). Five patients (3.3%) had the mesh removed due to deep infection, chronic pain or early recurrence. The training level of the surgeon had no influence on the incidence of complications. A 93.8% majority of the patients would recommend this specific procedure to others. The intraperitoneal placement of this composite mesh is associated with a high level of patient satisfaction as well as low rates of both recurrence and infection.

  • 出版日期2010-12