摘要

This paper presents a comparative investigation, design and development issues about six different single-stage topologies, applied as electronic ballasts, for electrodeless fluorescent lamps. The ballast is intended to feed a 100 W lamp at 250 kHz, with dimming feature. The proposed topologies use different converters for the power factor correction (PFC) stage: Buck-Boost, SEPIC, Zeta, Cuk, Flyback, and Boost. All of them operate in discontinuous conduction mode. A resonant half-bridge inverter is used as lamp power control (PC) stage. The integration of both stages (PFC and PC) is proposed in this paper. In this way, it is possible to reduce the number of active switches, as well as simplify the required driving and control circuitry. Experimental results demonstrate the feasibility of the proposed dimming technique that achieved around 56% lamp power dimming, from 100 W down to 44 W. The implemented topologies attained high average power factor (>0.98), and low line current average total harmonic distortion (<15.3%). A comparison among all the proposed topologies in terms of power factor, harmonic distortion, efficiency and number of components is presented. Finally, a comparison between an integrated and a nonintegrated SEPIC half-bridge converter is also performed.

  • 出版日期2015-4