摘要
Color is one of the quality determining factors for pepper powder. To measure the color of pepper powder, several methods including high-performance liquid chromatography (HPLC), thin layer chromatography (TLC), and ASTA-20 have been used. Among the methods, the ASTA-20 method is most widely used for color measurement of a large number of samples because of its simplicity and accuracy. However it requires time consuming preprocessing steps and generates chemical waste containing acetone. As an alternative, we developed a fast and simple method based on a visible/near infrared (Vis/NIR) hyperspectral method to measure the color of pepper powder. To evaluate correlation between the ASTA-20 and the visible/near infrared (Vis/NIR) hyperspectral methods, we first measured the color of a total of 488 pepper powder samples using the two methods. Then, a partial least squares (PLS) model was postulated using the color values of randomly selected 3 66 samples to predict ASTA values of unknown samples. When the ASTA values predicted by the PLS model were compared with those of the ASTA-20 method for 122 samples not used for model development, there was very high correlation between two methods (R-2 = 0.88) demonstrating reliability of Vis/NIR hyperspectral method. We believe that this simple and fast method is suitable for high-throughput screening of a large number of samples because this method does not require preprocessing steps required for the ASTA-20 method, and takes less than 30 min to measure the color of pepper powder.
- 出版日期2015-6