摘要

Power converters with high switching frequency generate conducted electromagnetic interference (EMI) noise. EMI filters are thus widely used to reduce these conducted noises for the compliance with electromagnetic compatibility standards. In this paper, a high-frequency (HF) equivalent circuit model for common mode (CM) chokes used in EMI filters is proposed together with its parameter extraction procedure. This procedure is based on impedance measurements and it incorporates an iterative rational function approximation fitting algorithm to extract the parameters in the model. The proposed model and procedure is applied to a planar CM choke which is used to realize an EMI filter. The simulated results of the filter show good agreement with the experimental ones. This extraction procedure is quite general and it can also be extended to identify the HF model of other passive components.

  • 出版日期2013-3