Densitometric evaluation might prevent failure of knee artroplasty for aseptic loosening. An 8-year observational controlled study

作者:Saviola Gianantonio*; Zaghini Irene; Abdi Ali Lul; Ferlini Gregorio; Sacco Silvano; Rossini Maurizio
来源:Saudi Medical Journal, 2016, 37(2): 212-214.
DOI:10.15537/smj.2016.2.12724

摘要

Objectives: To study the correlation between quantitative ultrasound (QUS) expressed as stiffness index (SI) and the risk of aseptic loosening of knee arthroplasty. Methods: An observational retrospective controlled study was performed on 85 female patients (mean age: 73.3 years) divided into 2 groups from January 2007 to March 2015 and carried out at the Orthopedic Rehabilitation Unit, Casa di Cura Eremo, Arco, Trento, Italy. Group A included 42 patients who had undergone a revision of knee prosthesis for asepticloosening, and group B included 43 age-matched patients who underwent primary replacement of the knee without following aseptic loosening. Patients in both groups were evaluated for SI with Achilles - QUS system at the same side of the surgery. Results: In group A, 20/42 patients (47.6%) had an SI T-score below -2.5. In group B, 14/43 (32.5%) patients had a SI T-score below -2.5. The difference between the 2 groups was statistically significant (p=0.015). Conclusion: Stiffness index appears to be an important predictor of aseptic loosening of the knee prosthesis. Therefore, densitometric evaluation, including SI, may be recommended before surgical knee replacement.

  • 出版日期2016-2

全文