A Micro-Computed Tomography Technique to Study the Quality of Fibre Optics Embedded in Composite Materials

作者:Chiesura Gabriele*; Luyckx Geert; Voet Eli; Lammens Nicolas; Van Paepegem Wim; Degrieck Joris; Dierick Manuel; Van Hoorebeke Luc; Vanderniepen Pieter; Sulejmani Sanne; Sonnenfeld Camille; Geernaert Thomas; Berghmans Francis
来源:Sensors (Switzerland), 2015, 15(5): 10852-10871.
DOI:10.3390/s150510852

摘要

Quality of embedment of optical fibre sensors in carbon fibre-reinforced polymers plays an important role in the resultant properties of the composite, as well as for the correct monitoring of the structure. Therefore, availability of a tool able to check the optical fibre sensor-composite interaction becomes essential. High-resolution 3D X-ray Micro-Computed Tomography, or Micro-CT, is a relatively new non-destructive inspection technique which enables investigations of the internal structure of a sample without actually compromising its integrity. In this work the feasibility of inspecting the position, the orientation and, more generally, the quality of the embedment of an optical fibre sensor in a carbon fibre reinforced laminate at unit cell level have been proven.

  • 出版日期2015-5