Assessment of Workspace Attributes Under Simulated Index Finger Proximal Interphalangeal Arthrodesis

作者:Arauz Paul G; Sisto Sue A; Kao Imin
来源:Journal of Biomechanical Engineering, 2016, 138(5): 051005.
DOI:10.1115/1.4032967

摘要

<jats:p>This article presented an assessment of quantitative measures of workspace (WS) attributes under simulated proximal interphalangeal (PIP) joint arthrodesis of the index finger. Seven healthy subjects were tested with the PIP joint unconstrained (UC) and constrained to selected angles using a motion analysis system. A model of the constrained finger was developed in order to address the impact of the inclusion of prescribed joint arthrodesis angles on WS attributes. Model parameters were obtained from system identification experiments involving flexion–extension (FE) movements of the UC and constrained finger. The data of experimental FE movements of the constrained finger were used to generate the two-dimensional (2D) WS boundaries and to validate the model. A weighted criterion was formulated to define an optimal constraint angle among several system parameters. Results indicated that a PIP joint immobilization angle of 40–50 deg of flexion maximized the 2D WS. The analysis of the aspect ratio of the 2D WS indicated that the WS was more evenly distributed as the imposed PIP joint constraint angle increased. With the imposed PIP joint constraint angles of 30 deg, 40 deg, 50 deg, and 60 deg of flexion, the normalized maximum distance of fingertip reach was reduced by approximately 3%, 4%, 7%, and 9%, respectively.</jats:p>

  • 出版日期2016-5