An automatic gain adjustment Campbell integrator for neutron flux detection in ITER

作者:Cao Hongrui*; Li Shiping; Xu Xiufeng; Tang Shibiao; Yang Jinwei; Yang Qingwei; Yin Zejie
来源:Nuclear Science and Techniques, 2012, 23(2): 114-117.

摘要

Neutron Flux Monitor, a key diagnostic system in International Thermonuclear Experimental Reactor, may provide for reading a series of important parameters in fusion reaction process. We designed an important part of its main electronic system - Automatic Gain Adjustment Campbell Integrator (AGACI), expanding the detecting neutron counting rate of 10(4)-10(8) cps (counts per second). The total gain of AGACI in five files is divided into 1, 10, 100, 1000, and 10 000 times, and can be automatically adjusted. The linear correlation coefficient (R) is more than 0.9999 in AGACI working range.

  • 出版日期2012-4-20
  • 单位核探测与核电子学国家重点实验室; 中国科学技术大学; 核工业西南物理研究院