Cocaine is a common drug of abuse. To detect its use, a screening detection concentration for the cocaine metabolite benzoylecgonine is commonly set at 150 ng/mL and its confirmatory cut-off is set at 100 ng/mL. Studies have suggested that these cut-offs may be set too high, allowing some patients with this substance abuse problem to be missed or improperly monitored. With the advent of liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology it is possible to reliably detect and quantify lower concentrations of its metabolite benzoylecgonine as part of a larger drug panel. One purpose of the study was to establish if there was a significant increase in detection of cocaine use with a ten-fold more sensitive cut-off. A very sensitive dilute and shoot assay for benzoylecgonine was developed with a lower limit of quantitation of 5 ng/mL. Validation of the 5 ng/mL cut-off was achieved by plotting all the positive cocaine observations as a frequency distribution on a logarithmic scale. The number of positive results with measurable concentrations below the typical industry 100 ng/mL cut-off level but above the high sensitivity 5 ng/mL cut-off level was observed to be 51.9% of the observed positives. The lower cut-off also allowed a re-evaluation of the window of detection after cessation of use. It was observed to be between 17 and 22 days.