Examining the influence of distal radius orientation on distal radioulnar joint contact using a finite element model

作者:Greybe Desney*; Boland Michael R; Wu Tim; Mithraratne Kumar
来源:International Journal for Numerical Methods in Biomedical Engineering, 2016, 32(11): e02766.
DOI:10.1002/cnm.2766

摘要

Distal radius malunion is a problem that is common to distal radius fractures and can affect the contact mechanics of the distal radioulnar joint (DRUJ). The goal of this study was to use a computational model of the DRUJ to investigate the influence distal radius orientation has on its contact mechanics. Detailed, finite element models of the radius and ulna bones were constructed from magnetic resonance imaging data. The orientation of the distal radius was rotated in 2 degrees increments about three orthogonal axes representing dorsal-palmar rotation, radial-ulnar rotation and anteversion-retroversion. A computational model was used to predict joint contact at the DRUJ in each condition. Joint contact was found to be most sensitive to dorsal rotation of the distal radius, while radial and ulnar rotation did not substantially affect joint contact pressure. Slight retroversion was found to lower joint contact pressure. In most cases, more than 6 degrees rotation in a given direction resulted in dislocation of the DRUJ, so that adaptation at the joint would be required to maintain articular contact. The joint contact model implemented in this study allowed the relationship between distal radius orientation and DRUJ contact to be examined systematically, in a way that is difficult to achieve using a cadaver-based approach. The results demonstrated the distal radius displacements most critical for maintaining healthy joint mechanics at the DRUJ. It is important that clinicians consider the influence of distal radius malunion and its treatment on DRUJ mechanics, in addition to its consequences for wrist function and forearm rotation.

  • 出版日期2016-11

全文